šŸŽ‰ Up to 70% Off Selected ItemsShop Sale
HomeStore

Goodman GDVT801005CX 80% AFUE 100,000 BTUH/H Gas Furnace Variable Speed ECM, Two Stage, Downflow/Horizontal, Low NOx - 21" Width

1 / 2

Goodman GDVT801005CX 80% AFUE 100,000 BTUH/H Gas Furnace Variable Speed ECM, Two Stage, Downflow/Horizontal, Low NOx - 21" Width

Goodman GDVT801005CX 80% AFUE 100,000 BTUH/H Gas Furnace Variable Speed ECM, Two Stage, Downflow/Horizontal, Low NOx - 21" Width

Upgrade your heating system with the Goodman GDVT801005CX 80% AFUE 100,000 BTUH/H Gas Furnace Variable Speed ECM, Two Stage, Downflow/Horizontal, Low NOx - 21" Width, engineered for reliability, quiet comfort, and efficient performance. With integrated ComfortBridgeā„¢ technology, this unit adapts to home heating demand while maintaining consistent comfort.

Standard Features:

  • Integrated communicating ComfortBridgeā„¢ technology
  • Two-stage gas valve provides quiet, economical heating
  • Commissioning and diagnostics via on board Bluetooth with the CoolCloudā„¢ phone and tablet application
  • Efficient and quiet variable-speed ECM circulator motor gently ramps up or down according to heating or cooling demand
  • SureStartĀ® Silicon Nitride igniter designed for long igniter life
  • Self-diagnostic control board with constant memory fault code history output to a triple 7-segment display
  • Low constant fan speed circulates air throughout the home
  • Quiet, two-speed induced draft blower
  • California Low NOx emissions-compliant models available
  • Can no longer be installed in California’s South Coast Air Quality Management District (SCAQMD) on or after October 1, 2019.
  • AHRI Certified; ETL Listed

Cabinet Features:

  • Fully insulated, heavy-gauge steel cabinet with durable baked-enamel finish
  • Multi-position installation:
    • GRVT80: upflow, horizontal left or right
    • GDVT80: downflow, horizontal left or right
  • Removable bottom for side- or bottom-return applications
  • Convenient left or right connection for gas/electric service
  • Cabinet air leakage ≤ 2%
  • Coil and furnace fit flush for most installations

Warranty:

  • 10-Year Unit Replacement Limited Warranty
  • 10-Year Parts Limited Warranty
  • 20-Year Heat Exchanger Limited Warranty + One-Time Heat Exchanger Replacement Limited Warranty
  • See the warranty document here for full warranty details

Goodman GDVT801005CX 80% AFUE 100,000 BTUH/H Gas Furnace Variable Speed ECM, Two Stage, Downflow/Horizontal, Low NOx - 21" Width Specifications:

Brand Goodman
Model GDVT801005CX
R-32 Compliant Yes
Heating Capacity

High Fire Input (BTU/h)¹: 100,000

High Fire Output (BTU/h)¹:

  • Natural Gas: 80,000
  • LP Gas: 80,000

Low Fire Input (BTU/h)¹: 70,000

Low Fire Output (BTU/h)¹:

  • Natural Gas: 56,000
  • LP Gas: 56,000

AFUE²: 80

Available AC @ 0.5" ESP: 2.0 – 5.0

Temp Rise Range (°F) High/Low Fire: 20–50 / 20–50

Circulator Blower

Size (D Ɨ W): 10" Ɨ 10"

Horsepower - RPM: 3/4

Speed: Variable

Vent Diameter: 4"

No. of Burners: 5

Electrical Data

Min. Circuit Ampacity³: 10.8

Max. Overcurrent Device (amps)⁓: 15

CFM

2000

Filter Size (in²)

(2) 14 x 20 or (1) 20 x 25 (Top Return)

Ship Weight

Ship Weight (lbs): 129

DimensionsĀ 

21ā€ x 28ā€ x 33ā…œ" (W x D x H)

ResourcesĀ 

Ā 

¹Natural Gas BTU/h; for altitudes above from 0’ to 4,500’ above sea level, reduce input rating 4% for each 1,000’ above 4,500’ altitude. Low-fire rate is 70% of high-fire rate.

²DOE AFUE based upon Isolated Combustion System (ICS)

³Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

⁓Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.

Notes

  • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
  • Gas Service Connection Ā½ā€ FPT
  • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.

Goodman GDVT801005CX 80% AFUE 100,000 BTUH/H Gas Furnace Variable Speed ECM, Two Stage, Downflow/Horizontal, Low NOx - 21" Width

Upgrade your heating system with the Goodman GDVT801005CX 80% AFUE 100,000 BTUH/H Gas Furnace Variable Speed ECM, Two Stage, Downflow/Horizontal, Low NOx - 21" Width, engineered for reliability, quiet comfort, and efficient performance. With integrated ComfortBridgeā„¢ technology, this unit adapts to home heating demand while maintaining consistent comfort.

Standard Features:

  • Integrated communicating ComfortBridgeā„¢ technology
  • Two-stage gas valve provides quiet, economical heating
  • Commissioning and diagnostics via on board Bluetooth with the CoolCloudā„¢ phone and tablet application
  • Efficient and quiet variable-speed ECM circulator motor gently ramps up or down according to heating or cooling demand
  • SureStartĀ® Silicon Nitride igniter designed for long igniter life
  • Self-diagnostic control board with constant memory fault code history output to a triple 7-segment display
  • Low constant fan speed circulates air throughout the home
  • Quiet, two-speed induced draft blower
  • California Low NOx emissions-compliant models available
  • Can no longer be installed in California’s South Coast Air Quality Management District (SCAQMD) on or after October 1, 2019.
  • AHRI Certified; ETL Listed

Cabinet Features:

  • Fully insulated, heavy-gauge steel cabinet with durable baked-enamel finish
  • Multi-position installation:
    • GRVT80: upflow, horizontal left or right
    • GDVT80: downflow, horizontal left or right
  • Removable bottom for side- or bottom-return applications
  • Convenient left or right connection for gas/electric service
  • Cabinet air leakage ≤ 2%
  • Coil and furnace fit flush for most installations

Warranty:

  • 10-Year Unit Replacement Limited Warranty
  • 10-Year Parts Limited Warranty
  • 20-Year Heat Exchanger Limited Warranty + One-Time Heat Exchanger Replacement Limited Warranty
  • See the warranty document here for full warranty details

Goodman GDVT801005CX 80% AFUE 100,000 BTUH/H Gas Furnace Variable Speed ECM, Two Stage, Downflow/Horizontal, Low NOx - 21" Width Specifications:

Brand Goodman
Model GDVT801005CX
R-32 Compliant Yes
Heating Capacity

High Fire Input (BTU/h)¹: 100,000

High Fire Output (BTU/h)¹:

  • Natural Gas: 80,000
  • LP Gas: 80,000

Low Fire Input (BTU/h)¹: 70,000

Low Fire Output (BTU/h)¹:

  • Natural Gas: 56,000
  • LP Gas: 56,000

AFUE²: 80

Available AC @ 0.5" ESP: 2.0 – 5.0

Temp Rise Range (°F) High/Low Fire: 20–50 / 20–50

Circulator Blower

Size (D Ɨ W): 10" Ɨ 10"

Horsepower - RPM: 3/4

Speed: Variable

Vent Diameter: 4"

No. of Burners: 5

Electrical Data

Min. Circuit Ampacity³: 10.8

Max. Overcurrent Device (amps)⁓: 15

CFM

2000

Filter Size (in²)

(2) 14 x 20 or (1) 20 x 25 (Top Return)

Ship Weight

Ship Weight (lbs): 129

DimensionsĀ 

21ā€ x 28ā€ x 33ā…œ" (W x D x H)

ResourcesĀ 

Ā 

¹Natural Gas BTU/h; for altitudes above from 0’ to 4,500’ above sea level, reduce input rating 4% for each 1,000’ above 4,500’ altitude. Low-fire rate is 70% of high-fire rate.

²DOE AFUE based upon Isolated Combustion System (ICS)

³Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

⁓Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.

Notes

  • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
  • Gas Service Connection Ā½ā€ FPT
  • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.
$762.00

Original: $2,540.00

-70%
Goodman GDVT801005CX 80% AFUE 100,000 BTUH/H Gas Furnace Variable Speed ECM, Two Stage, Downflow/Horizontal, Low NOx - 21" Width—

$2,540.00

$762.00

Description

Goodman GDVT801005CX 80% AFUE 100,000 BTUH/H Gas Furnace Variable Speed ECM, Two Stage, Downflow/Horizontal, Low NOx - 21" Width

Upgrade your heating system with the Goodman GDVT801005CX 80% AFUE 100,000 BTUH/H Gas Furnace Variable Speed ECM, Two Stage, Downflow/Horizontal, Low NOx - 21" Width, engineered for reliability, quiet comfort, and efficient performance. With integrated ComfortBridgeā„¢ technology, this unit adapts to home heating demand while maintaining consistent comfort.

Standard Features:

  • Integrated communicating ComfortBridgeā„¢ technology
  • Two-stage gas valve provides quiet, economical heating
  • Commissioning and diagnostics via on board Bluetooth with the CoolCloudā„¢ phone and tablet application
  • Efficient and quiet variable-speed ECM circulator motor gently ramps up or down according to heating or cooling demand
  • SureStartĀ® Silicon Nitride igniter designed for long igniter life
  • Self-diagnostic control board with constant memory fault code history output to a triple 7-segment display
  • Low constant fan speed circulates air throughout the home
  • Quiet, two-speed induced draft blower
  • California Low NOx emissions-compliant models available
  • Can no longer be installed in California’s South Coast Air Quality Management District (SCAQMD) on or after October 1, 2019.
  • AHRI Certified; ETL Listed

Cabinet Features:

  • Fully insulated, heavy-gauge steel cabinet with durable baked-enamel finish
  • Multi-position installation:
    • GRVT80: upflow, horizontal left or right
    • GDVT80: downflow, horizontal left or right
  • Removable bottom for side- or bottom-return applications
  • Convenient left or right connection for gas/electric service
  • Cabinet air leakage ≤ 2%
  • Coil and furnace fit flush for most installations

Warranty:

  • 10-Year Unit Replacement Limited Warranty
  • 10-Year Parts Limited Warranty
  • 20-Year Heat Exchanger Limited Warranty + One-Time Heat Exchanger Replacement Limited Warranty
  • See the warranty document here for full warranty details

Goodman GDVT801005CX 80% AFUE 100,000 BTUH/H Gas Furnace Variable Speed ECM, Two Stage, Downflow/Horizontal, Low NOx - 21" Width Specifications:

Brand Goodman
Model GDVT801005CX
R-32 Compliant Yes
Heating Capacity

High Fire Input (BTU/h)¹: 100,000

High Fire Output (BTU/h)¹:

  • Natural Gas: 80,000
  • LP Gas: 80,000

Low Fire Input (BTU/h)¹: 70,000

Low Fire Output (BTU/h)¹:

  • Natural Gas: 56,000
  • LP Gas: 56,000

AFUE²: 80

Available AC @ 0.5" ESP: 2.0 – 5.0

Temp Rise Range (°F) High/Low Fire: 20–50 / 20–50

Circulator Blower

Size (D Ɨ W): 10" Ɨ 10"

Horsepower - RPM: 3/4

Speed: Variable

Vent Diameter: 4"

No. of Burners: 5

Electrical Data

Min. Circuit Ampacity³: 10.8

Max. Overcurrent Device (amps)⁓: 15

CFM

2000

Filter Size (in²)

(2) 14 x 20 or (1) 20 x 25 (Top Return)

Ship Weight

Ship Weight (lbs): 129

DimensionsĀ 

21ā€ x 28ā€ x 33ā…œ" (W x D x H)

ResourcesĀ 

Ā 

¹Natural Gas BTU/h; for altitudes above from 0’ to 4,500’ above sea level, reduce input rating 4% for each 1,000’ above 4,500’ altitude. Low-fire rate is 70% of high-fire rate.

²DOE AFUE based upon Isolated Combustion System (ICS)

³Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

⁓Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.

Notes

  • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
  • Gas Service Connection Ā½ā€ FPT
  • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.