Goodman 5 Ton Cooling / 140,000 BTU Heating 81% AFUE 15.2 SEER2 2-Stage Gas/Electric Package Unit - GPGM56014041
Goodman 5 Ton Cooling / 140,000 BTU Heating 81% AFUE 15.2 SEER2 2-Stage Gas/Electric Package Unit - GPGM56014041
The Goodman 5 Ton Cooling / 140,000 BTU Heating 81% AFUE 15.2 SEER2 2-Stage Gas/Electric Package Unit - GPGM56014041 utilizes a reliable Direct-Spark Ignition System and integrated controls with on-board diagnostics, plus a combination redundant gas valve and regulator for further safety and reliability. The Goodman 5 Ton Cooling / 140,000 BTU Heating 81% AFUE 15.2 SEER2 2-Stage Gas/Electric Package Unit - GPGM56014041 also boasts a high-performance, energy-efficient compressor, which operates in tandem with our high-efficiency coil. The coil is made of refrigeration-grade copper tubing and aluminum fins in a design that maximizes surface area. These high-quality components together cool your home effectively while saving you money on your energy bills as compared to lower SEER units.
Standard Features:
- Durable, corrosion-resistant T-140 aluminized steel tubular heat exchanger
- High-efficiency two-stage scroll compressor
- Convertible airflow: horizontal or downflow application
- Variable-speed ECM indoor blower motor
- Copper tube/aluminum fin condenser coil
- Aluminum-copper evaporator coil on 5-ton units
- Power-assisted combustion
- Loss-of-charge protection & high-pressure switch
- Two-stage gas valve; natural gas with easy conversion to propane with accessory kit
- Direct spark ignition system includes a microprocessor-based control for the entire ignition sequence
- All blower operation and all safety circuits complete with self-diagnostics
- All models comply with California Low NOx emission standards (40ng/J NOx)
- This furnace does not comply with the SCAQMD Rule 1111 nor the SJVAPCD Rule 4905 14 ng/J NOx emission limit and therefore is not eligible for installation in Californiaâs South Coast Air Quality Management District (SCAQMD) nor the San Joaquin Valley Air Pollution Control District (SJVAPCD)
- AHRI Certified; ETL Listed
Cabinet Features:
- Fully insulated heavy-gauge, zinc-coated steel cabinet with UV-resistant powder-paint finish
- Aluminum foil-facing internal insulation reinforced with fiberglass scrim
- Convenient access panels
- Bottom, 2â high base rails for easier handling
- When properly anchored, meets the 2020 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
- Meets cabinet air leakage requirements when tested in accordance with ASHRAE standard 193
Specifications:
| Brand | Goodman |
| Model | GPGM56014041 |
| Warranty |
10 Year Parts Warranty with online registration 10 Year Compressor Warranty with online registration 20 Year Heat Exchanger Warranty with online registration |
| Refrigerant | R-410A |
| Configuration | Downflow / Horizontal |
| Energy Star Certified | No |
| Cooling Capacity |
Total BTU/h: 58,000 Sensible BTU/h: 42,600 SEER2 / EER2: 15.2/ 11.2 Decibels: 78 AHRI Number: 209319573 |
| Heating Capacity (BTU/H) |
High-Fire Input / Output: 135,000 / 109,350 Low-Fire Input / Output: 101,250 / 82,000 AFUE: 81 High/Low Temperature Rise Range: 35-65/25-55 No. of Burners: 6 |
| Evaporator Motor |
Type: ECM Wheel (D x W): 11â x 10â Indoor Nominal CFM: 2,000 No. of Speeds: 5 Horsepower: 1 |
| Evaporator Coil |
Face Area (ft²): 9.2 Rows Deep/Fins per Inch: 4 / 16 Piston Size (Cooling): TXV Filter Size (ft²): (1)14X20X2, (2)20X20X2 Drain Size (NPT): 3/4" Refrigerant Charge (oz.): 150 |
| Condenser Fan/Coil |
Horsepower - RPM: 1/3 - 1,000 Diameter / # of Blades: 22â / 3 Outdoor Nominal CFM: 4,200 Face Area (ft²): 19 Rows Deep/Fins per Inch: 2 / 28 |
| Compressor |
Quantity / Type / Stage: 1 / Scroll / 2 Compressor RLA/LRA: 27/ 139.9 |
| Electrical Data |
Voltage-Phase (Frequency 60Hz): 208/230-1 Indoor Blower FLA/LRA: 6.9 Outdoor Fan FLA/LRA: 2.8 / 4.4 Min. Circuit Ampacity: 43.3 Max. Overcurrent Protection: 70 amps |
| Operating / Ship Weights (lbs) | 655 / 713 |
| Dimensions (W x D x H) | 73-3/8 x 47-5/8 x 43-1/2 inches |
| Duct Openings Dimensions |
Supply (W x H): 17 x 12 inches Return (W x H): 11 x 25 inches |
Product Information and Guides:
Goodman 5 Ton Cooling / 140,000 BTU Heating 81% AFUE 15.2 SEER2 2-Stage Gas/Electric Package Unit - GPGM56014041
The Goodman 5 Ton Cooling / 140,000 BTU Heating 81% AFUE 15.2 SEER2 2-Stage Gas/Electric Package Unit - GPGM56014041 utilizes a reliable Direct-Spark Ignition System and integrated controls with on-board diagnostics, plus a combination redundant gas valve and regulator for further safety and reliability. The Goodman 5 Ton Cooling / 140,000 BTU Heating 81% AFUE 15.2 SEER2 2-Stage Gas/Electric Package Unit - GPGM56014041 also boasts a high-performance, energy-efficient compressor, which operates in tandem with our high-efficiency coil. The coil is made of refrigeration-grade copper tubing and aluminum fins in a design that maximizes surface area. These high-quality components together cool your home effectively while saving you money on your energy bills as compared to lower SEER units.
Standard Features:
- Durable, corrosion-resistant T-140 aluminized steel tubular heat exchanger
- High-efficiency two-stage scroll compressor
- Convertible airflow: horizontal or downflow application
- Variable-speed ECM indoor blower motor
- Copper tube/aluminum fin condenser coil
- Aluminum-copper evaporator coil on 5-ton units
- Power-assisted combustion
- Loss-of-charge protection & high-pressure switch
- Two-stage gas valve; natural gas with easy conversion to propane with accessory kit
- Direct spark ignition system includes a microprocessor-based control for the entire ignition sequence
- All blower operation and all safety circuits complete with self-diagnostics
- All models comply with California Low NOx emission standards (40ng/J NOx)
- This furnace does not comply with the SCAQMD Rule 1111 nor the SJVAPCD Rule 4905 14 ng/J NOx emission limit and therefore is not eligible for installation in Californiaâs South Coast Air Quality Management District (SCAQMD) nor the San Joaquin Valley Air Pollution Control District (SJVAPCD)
- AHRI Certified; ETL Listed
Cabinet Features:
- Fully insulated heavy-gauge, zinc-coated steel cabinet with UV-resistant powder-paint finish
- Aluminum foil-facing internal insulation reinforced with fiberglass scrim
- Convenient access panels
- Bottom, 2â high base rails for easier handling
- When properly anchored, meets the 2020 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
- Meets cabinet air leakage requirements when tested in accordance with ASHRAE standard 193
Specifications:
| Brand | Goodman |
| Model | GPGM56014041 |
| Warranty |
10 Year Parts Warranty with online registration 10 Year Compressor Warranty with online registration 20 Year Heat Exchanger Warranty with online registration |
| Refrigerant | R-410A |
| Configuration | Downflow / Horizontal |
| Energy Star Certified | No |
| Cooling Capacity |
Total BTU/h: 58,000 Sensible BTU/h: 42,600 SEER2 / EER2: 15.2/ 11.2 Decibels: 78 AHRI Number: 209319573 |
| Heating Capacity (BTU/H) |
High-Fire Input / Output: 135,000 / 109,350 Low-Fire Input / Output: 101,250 / 82,000 AFUE: 81 High/Low Temperature Rise Range: 35-65/25-55 No. of Burners: 6 |
| Evaporator Motor |
Type: ECM Wheel (D x W): 11â x 10â Indoor Nominal CFM: 2,000 No. of Speeds: 5 Horsepower: 1 |
| Evaporator Coil |
Face Area (ft²): 9.2 Rows Deep/Fins per Inch: 4 / 16 Piston Size (Cooling): TXV Filter Size (ft²): (1)14X20X2, (2)20X20X2 Drain Size (NPT): 3/4" Refrigerant Charge (oz.): 150 |
| Condenser Fan/Coil |
Horsepower - RPM: 1/3 - 1,000 Diameter / # of Blades: 22â / 3 Outdoor Nominal CFM: 4,200 Face Area (ft²): 19 Rows Deep/Fins per Inch: 2 / 28 |
| Compressor |
Quantity / Type / Stage: 1 / Scroll / 2 Compressor RLA/LRA: 27/ 139.9 |
| Electrical Data |
Voltage-Phase (Frequency 60Hz): 208/230-1 Indoor Blower FLA/LRA: 6.9 Outdoor Fan FLA/LRA: 2.8 / 4.4 Min. Circuit Ampacity: 43.3 Max. Overcurrent Protection: 70 amps |
| Operating / Ship Weights (lbs) | 655 / 713 |
| Dimensions (W x D x H) | 73-3/8 x 47-5/8 x 43-1/2 inches |
| Duct Openings Dimensions |
Supply (W x H): 17 x 12 inches Return (W x H): 11 x 25 inches |
Product Information and Guides:
Description
Goodman 5 Ton Cooling / 140,000 BTU Heating 81% AFUE 15.2 SEER2 2-Stage Gas/Electric Package Unit - GPGM56014041
The Goodman 5 Ton Cooling / 140,000 BTU Heating 81% AFUE 15.2 SEER2 2-Stage Gas/Electric Package Unit - GPGM56014041 utilizes a reliable Direct-Spark Ignition System and integrated controls with on-board diagnostics, plus a combination redundant gas valve and regulator for further safety and reliability. The Goodman 5 Ton Cooling / 140,000 BTU Heating 81% AFUE 15.2 SEER2 2-Stage Gas/Electric Package Unit - GPGM56014041 also boasts a high-performance, energy-efficient compressor, which operates in tandem with our high-efficiency coil. The coil is made of refrigeration-grade copper tubing and aluminum fins in a design that maximizes surface area. These high-quality components together cool your home effectively while saving you money on your energy bills as compared to lower SEER units.
Standard Features:
- Durable, corrosion-resistant T-140 aluminized steel tubular heat exchanger
- High-efficiency two-stage scroll compressor
- Convertible airflow: horizontal or downflow application
- Variable-speed ECM indoor blower motor
- Copper tube/aluminum fin condenser coil
- Aluminum-copper evaporator coil on 5-ton units
- Power-assisted combustion
- Loss-of-charge protection & high-pressure switch
- Two-stage gas valve; natural gas with easy conversion to propane with accessory kit
- Direct spark ignition system includes a microprocessor-based control for the entire ignition sequence
- All blower operation and all safety circuits complete with self-diagnostics
- All models comply with California Low NOx emission standards (40ng/J NOx)
- This furnace does not comply with the SCAQMD Rule 1111 nor the SJVAPCD Rule 4905 14 ng/J NOx emission limit and therefore is not eligible for installation in Californiaâs South Coast Air Quality Management District (SCAQMD) nor the San Joaquin Valley Air Pollution Control District (SJVAPCD)
- AHRI Certified; ETL Listed
Cabinet Features:
- Fully insulated heavy-gauge, zinc-coated steel cabinet with UV-resistant powder-paint finish
- Aluminum foil-facing internal insulation reinforced with fiberglass scrim
- Convenient access panels
- Bottom, 2â high base rails for easier handling
- When properly anchored, meets the 2020 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
- Meets cabinet air leakage requirements when tested in accordance with ASHRAE standard 193
Specifications:
| Brand | Goodman |
| Model | GPGM56014041 |
| Warranty |
10 Year Parts Warranty with online registration 10 Year Compressor Warranty with online registration 20 Year Heat Exchanger Warranty with online registration |
| Refrigerant | R-410A |
| Configuration | Downflow / Horizontal |
| Energy Star Certified | No |
| Cooling Capacity |
Total BTU/h: 58,000 Sensible BTU/h: 42,600 SEER2 / EER2: 15.2/ 11.2 Decibels: 78 AHRI Number: 209319573 |
| Heating Capacity (BTU/H) |
High-Fire Input / Output: 135,000 / 109,350 Low-Fire Input / Output: 101,250 / 82,000 AFUE: 81 High/Low Temperature Rise Range: 35-65/25-55 No. of Burners: 6 |
| Evaporator Motor |
Type: ECM Wheel (D x W): 11â x 10â Indoor Nominal CFM: 2,000 No. of Speeds: 5 Horsepower: 1 |
| Evaporator Coil |
Face Area (ft²): 9.2 Rows Deep/Fins per Inch: 4 / 16 Piston Size (Cooling): TXV Filter Size (ft²): (1)14X20X2, (2)20X20X2 Drain Size (NPT): 3/4" Refrigerant Charge (oz.): 150 |
| Condenser Fan/Coil |
Horsepower - RPM: 1/3 - 1,000 Diameter / # of Blades: 22â / 3 Outdoor Nominal CFM: 4,200 Face Area (ft²): 19 Rows Deep/Fins per Inch: 2 / 28 |
| Compressor |
Quantity / Type / Stage: 1 / Scroll / 2 Compressor RLA/LRA: 27/ 139.9 |
| Electrical Data |
Voltage-Phase (Frequency 60Hz): 208/230-1 Indoor Blower FLA/LRA: 6.9 Outdoor Fan FLA/LRA: 2.8 / 4.4 Min. Circuit Ampacity: 43.3 Max. Overcurrent Protection: 70 amps |
| Operating / Ship Weights (lbs) | 655 / 713 |
| Dimensions (W x D x H) | 73-3/8 x 47-5/8 x 43-1/2 inches |
| Duct Openings Dimensions |